Metered PDUs inotarisisa uye kuratidza mashandisiro emagetsi, ichibvumira vashandisi kutevedzera mashandisirwo esimba nemazvo. Kusiyana neizvi, maPDU asina kuverengerwa anogovera simba pasina kugona kwekutarisa. Kunzwisisa misiyano iyi kwakakosha pakugadzirisa manejimendi emagetsi munzvimbo dzedata uye kuona kushanda kwakanaka kwemidziyo yakaita seMetered Rack Mount PDU.
Key Takeaways
- Metered PDUs inopa chaiyo-nguva yekutarisayekushandiswa kwesimba, kubatsira vashandisi kugadzirisa mashandisirwo esimba nemazvo.
- Unmetered PDUs inopa inodhura-inoshanda mhinduro yekugovera simba rekutanga pasina yekutarisa kugona.
- Kusarudza iyo PDU yakakodzerazvinoenderana nezvido zvako zvekushanda, bhajeti, uye kana uchida simba rekutarisa.
Tsanangudzo yeMetered PDU
A Metered PDU(Power Distribution Unit) chishandiso chakakosha munzvimbo dzedata uye nharaunda dzeIT. Iyo haingogovera simba remagetsi kune akawanda maturusi asiwo inotarisisa uye inoratidza mashandisiro emagetsi munguva chaiyo-nguva. Izvi zviviri zvinoshanda zvinowedzera kuvimbika uye kugona kwekutonga kwesimba.
Zvimiro zveMetered Rack Mount PDU
Metered Rack Mount PDUs anouya akashongedzerwa akati wandeizvinhu zvinokoshaizvo zvinozvisiyanisa kubva kumaPDU akajairwa. Izvi zvinosanganisira:
- Digital Display: Yakavakirwa-mukati dhijitari inoratidza inoratidza chaiyo-nguva data nezvemagetsi emagetsi mashandisiro.
- Load Balancing: Metered PDUs anobatsira kuyera mitoro, kudzivirira kuwanda kwenyaya izvo zvinogona kutungamira mukukundikana kwemidziyo.
- Kuyera Basa: Ivo vanotarisisa mashandisirwo emidziyo yakabatana pamasoketi ega ega, vachipa ruzivo rwakadzama mukushandiswa kwesimba.
- Remote Access: Mamwe mamodheru anobvumira vashandisi kuwana yakayerwa data kure, kufambisa zvirinani kutonga kwesimba.
- Kuyera Kwekuchengetedza: Aya mayuniti anoyera yasara ikozvino kuitira kuchengetedza kwekushanda uye anogona kuseta zvikumbaridzo kukosha kune chenjedzo.
Heino pfupiso yeiyo tekinoroji yakatarwa inowanzo wanikwa mune metered rack gomo PDUs:
| Tsanangudzo | Tsanangudzo |
|---|---|
| Input Power Capacity | Kusvika ku67kVA |
| Input Currents | 12A kusvika 100A pamutsetse |
| Input Voltages | Zvisarudzo zvakasiyana kubva ku100V kusvika ku480V |
| Metering Accuracy | ±0.5% |
| Outlet Receptacle Density | Kusvikira ku54 zvitoro |
| Maximum Ambient Temperature | 60°C (140°F) |
| Relative Humidity | 5-90% RH (kushanda) |
Monitoring Mano
Iko kugona kwekutarisa kwemametered PDUs kwakakosha kune inoshanda manejimendi emagetsi. Ivo vanounganidza chaiyo-nguva data pane akasiyana paramita, kusanganisira:
- Zvazvino (A)
- Mvura (W)
- Voltage (V)
- Frequency (Hz)
Iyi data inobvumira vashandisi kutevedzera peak mutoro, simba chinhu, uye yakazara simba mashandisiro nekufamba kwenguva. Vashandisi vanogona kuwana ruzivo urwu kuburikidza nenzira dzekutarisa dzemunharaunda, dzakadai sezviratidzi zve LED uye LCD kuratidza. Pamusoro pezvo, akawanda metered PDUs anopa kure kutarisa kuburikidza newebhu interfaces uye simba manejimendi software, ichigonesa inoshanda data center management.
Tsanangudzo yeUnmetered PDU
An Unmetered PDU (Power Distribution Unit) inoshanda seyakajeka simba rekugovera mhinduro munzvimbo dze data uye IT nharaunda. Kusiyana nemametered PDUs, unmetered units inotarisa chete pakugovera magetsi pasina kupa chero kugona kwekutarisa. Izvi zviri nyore zvinovaita sarudzo yakakurumbira kune mamwe maapplication.
Zvimiro zveUnmetered PDU
Unmetered PDUs anouya ane akati wandei akakosha maficha anoenderana nekutanga simba rekugovera zvinodiwa. Izvi zvinosanganisira:
- Basic Power Distribution: Ivo vanogovera simba kune akawanda madivayiri pasina chero chekutarisa mabasa.
- Kusiyana-siyana Kwekugadzirisa: Unmetered PDUs anowanikwa mune akasiyana masisitimu, anosanganisira akachinjika uye akatwasuka dhizaini, kuti ikwane akasiyana rack setups.
- Cost-Inoshanda Solution: Aya mayunitsi anowanzo kudhura mari shoma pane mamwe ma metered, zvichiita kuti ive sarudzo inokwezva kumasangano anoona nezvebhajeti.
- Robust Design: Unmetered PDUs anowanzo ratidza kuvaka kwakasimba, kuve nechokwadi chekuita kwakavimbika munzvimbo dzinoda.
Kushaya Monitoring Mano
Kusavapo kwekugona kwekutarisa mumaPDU asina kuverengerwa kunogona kukanganisa zvakanyanya manejimendi emagetsi munzvimbo dzedata. Pasina chaiyo-nguva data, vashandisi vanosangana nematambudziko akati wandei:
- Unmonitored PDUs inogona kutungamira kumidziyo yekupisa uye kusashanda zvakanaka kwedunhu.
- Kushaikwa kwekutarisa kunokanganisa kuzivikanwa uye kugadzirisa nyaya dzemhando yemagetsi.
- Nzvimbo dzedata dzinogona kuwana nguva inodhura yekudzikira nekuda kwekusagadzikana kwesimba remagetsi.
Izvi zvinhu zvinosimbisa kukosha kwekutarisisa zvinodiwa pakusarudza PDU. NepomaPDU asina kuverengerwakupa mhinduro yakapfava uye inodhura, ivo vangasapa hutariro hunodiwa hwekutonga kwesimba rakakwana munzvimbo dzakaoma kunzwisisa.
Kuenzanisa kweMetered uye Unmetered PDUs

Zvakanakira Metered PDUs
Metered PDUs inopa akati wandei akakosha mabhenefiti anowedzerakutonga kwesimba munzvimbo dze data. Izvi zvinosanganisira:
| Advantage | Tsanangudzo |
|---|---|
| Kushanda Kwesimba | Metered PDUs inosimudzira kushanda kwesimba nekupa chaiyo zviyero zvekushandisa simba. Izvi zvinobvumira kutarisa kunoshanda uye kutonga kwekushandiswa kwesimba. |
| Cost Management | Ivo vanogonesa kugovaniswa kwakaringana kwemitengo yesimba munzvimbo dzakagovaniswa, kudzivirira kuwandisa kwedunhu uye optimizing simba rekugovera. Izvi pakupedzisira zvinoderedza mari yekushandisa. |
| Applications | Inowanzo shandiswa munzvimbo dzedata uye makamuri evhavha, metered PDUs inotsigira kugona kuronga uye kuwedzera nguva, kuve nechokwadi chekuvimbika munzvimbo dzakakosha dzemishoni. |
Masangano anogona zvakare kuona midziyo ine simba rakawanda kuburikidza neiyo data chaiyo pamashandisirwo emagetsi. Nekugonesa zvishandiso izvi, vanogona kudzikisa zvisina basa simba rekushandisa, zvichitungamira kudzikisa mabhiri ekushandisa. Ongororo yakaitwa neBitkom inoratidza kuti simba resimba rinogona kuvandudzwa ne30% kuburikidza nekuyera kushanda kwePDUs.
Zvakanakira zveUnmetered PDUs
Unmetered PDUs inopa mhinduro yakatwasuka yekugovera magetsi. Mabhenefiti avo ekutanga anosanganisira:
- Zviri nyore: Unmetered PDUs inotarisa chete pakugovera simba, zvichiita kuti zvive nyore kuisa nekushandisa.
- Mutengo-Kubudirira: Aya mayunitsi anowanzo kudhura zvishoma pane ma metered sarudzo, zvichiita kuti aenderane nemasangano anoona nezvebhajeti.
- Robust Design: Unmetered PDUs anowanzo ratidza kuvaka kwakasimba, kuve nechokwadi chekuita kwakavimbika munzvimbo dzinoda.
Shandisa Makesi eRudzi Rwose
Metered PDUs akanakira nharaunda uko kutarisa mashandisirwo emagetsi kwakakosha. Ivo vanokodzera nzvimbo dzedata, makamuri evhavha, uye mishoni-yakakosha maapplication. Kusiyana neizvi, maPDU asina kuverengerwa anoshanda zvakanaka mumaseti asina kuoma, senge mahofisi madiki kana nharaunda umo mashandisiro emagetsi asingade kutariswa.
Metered PDUs inopa chaiyo-nguva yekutarisa uye simba manejimendi, ichiita kuti ive yakanaka kune yakaoma nharaunda. Unmetered PDUs inopa inodhura-inoshanda mhinduro yekuseta kuri nyore. Paunosarudza pakati pavo, funga zvinhu zvakaita sezvinodiwa zvekushanda, bhajeti, uye zvinangwa zvekuteerera simba:
- Simba Zvinodiwa: Nzwisisa simba rose rinodiwa zvemidziyo yako.
- Advanced Features: Funga sarudzo senge chaiyo-nguva yekutarisa uye kure manejimendi.
Kusarudza iyo PDU chaiyo inogonesa kugovera magetsi uye kunoderedza njodzi dzine chekuita nemhando yesimba nyaya.
FAQ
Ndeipi basa rekutanga re metered PDU?
A metered PDUmonitors uye inoratidza chaiyo-nguva mashandisirwo emagetsi, achibvumira vashandisi kutonga mashandisiro esimba zvinobudirira.
Ndirini pandinofanira kusarudza PDU isina kuverengerwa?
Sarudza anPDU isina mitakune zvigadziriso zviri nyore uko kutarisa mashandisirwo emagetsi kusingakoshi uye kuchengetedza mari kuri pamberi.
Ini ndinogona kukwidziridza kubva kune isina metered kuenda kune metered PDU?
Ehe, kukwidziridza kubva kune isina metered kune metered PDU inogoneka. Ita shuwa kuenderana nezvivakwa zviripo usati waita switch.
Nguva yekutumira: Sep-27-2025