Data centers vateki vemagetsi. Nekukura kuri kuwedzera kwezvinhu zvedhijitari, data hombe, e-commerce, uye internet traffic, nzvimbo dzedhata dzave imwe yevatengi vemagetsi vari kukurumidza kukura pasi rose.
Zvinoenderana netsvagiridzo yazvino neResearchandMarkets, kushandiswa kwesimba kwenzvimbo dzedata kuri kukurumidza-kusimuka nekuda kwekukurumidza kuwedzera kwenyika uye kudiwa kwemasevhisi emagetsi anoshanda. Pakazosvika 2020, iyo data centre magetsi masevhisi musika inotarisirwa kukura paCompound Annual Growth Rate (CAGR) ye11.8%, inosvika $20.44 bhiriyoni.
Nzvimbo dzedata dzinoshandisa zvikamu zvitatu kubva muzana zvemagetsi epasi rose uye dzinotora 2% yehuwandu hwekuburitswa kwegasi regreenhouse. Kuendesa magetsi, kushandiswa, uye kutonga kwekupisa matambudziko akanyanya munzvimbo yedata center.
Kunyangwe kushanduka kudiki kwekupisa kwezvakatipoteredza kunogona kukanganisa zvakanyanya kushandiswa kwesimba. Naizvozvo, kutarisisa kwezvakatipoteredza nechaiyo-nguva uye yekuona data centre resource mepu inogona kubatsira data center administrator uye kuvazivisa kune zvingangoitika nyaya senge.mvura inodonha, fodya, uye kuvhura magonhi ekabati.
Izvisensorskubatsira kudzivirira kuwandisa, kupisa, electrostatic discharge, ngura, uye mapfupi maseketi, nezvimwe. YOSUNsmart PDUyakanyatsogadzirirwa kushanda nemasensa aya. Hedzino nzira shanu dzinokosha idzo ma sensors ezvakatipoteredza anogona kubatsira mamaneja enzvimbo yedata:
1.Tembiricha SensorsYekutonhodza Mutengo Kuchengeta: Data center midziyo inofanirwa kuchengetwa mukati meimwe tembiricha renji kuti ishande nemazvo uye kudzivirira kutadza kwehardware. Vanoda air conditioning uye ventilation kuti varambe vachitonhorera. Data center administrator vanogona kushandisa tembiricha data kukwenenzvera kutonhora masisitimu, kuona hotspots, uye kudzika pasi imwe kana kupfuura mudziyo sezvinodiwa. Tembiricha sensors pa rack inlets inopa yakanyatsojeka uye chaiyo-nguva data centre tembiricha maonero zvichienzaniswa nekuverenga kubva kuComputer Room Air Conditioning (CRAC) mayunitsi. Mamwe tembiricha uye humidity sensors akagadzirwa achitevera iyo American Society of Heating, Refrigerating, uye Air-Conditioning Engineers (ASHRAE) sensor yekuisa nhungamiro kuti uwane kuverenga kwakaringana uye kwakazara kubva kumusoro, pakati, uye pasi pemaraki.
2.Yakawedzera Uptime neAirflow Monitoring+ Airflow sensors inogonesa vatariri venzvimbo yedata kuti vatarise kutonhora kwemhepo uye mhepo inopisa inodzoka kuti ive nechokwadi chekuti inotonhorera inoshanda nemazvo. Ivo zvakare vanove nechokwadi chekuti kuyerera kwemhepo kuri padanho chairo kuitira kuti rack yese igamuchire inotonhorera inlet mweya. Differential air pressure sensors inobatsira maneja enzvimbo yedata kuona kutonhora kwakakwana kwemhepo. Masensa aya anogona kuona mutsauko wekumanikidzwa kwemhepo unogona kutungamira kune inopisa nzira / inotonhora nzira yekubuda uye kushandiswa kudzora zvikamu zveCRAC. Masensa epasi-pasi pemhepo anodzvinyirira anopa mhinduro kuComputer Room Air Handler (CRAH), CRAC, kana Building Management Systems (BMS) kugadzirisa kumhanya kwefan kuti isangane nepasi-pasi-pasi pekumanikidza setpoints.
3. Chengetedza Cabinet Racks neBata Kuvhara Sensors:Bata yekuvhara sensors inovimbisa kuchengetedzwa kwekabati racks. Inogona kushandiswa kukonzeresa zviitiko, sekutora mafoto nemakamera etiweki kana magonhi ekhabhineti akaonekwa akavhurika. Dry contact closure sensors inogona kushandiswa kune yechitatu-party madivayiri, akadai seutsi detectors, kutumira maaramu emoto kumamaneja e data data uye kuona musuwo wemagetsi wakavhurika / wekuvhara chimiro. Izvi zvinobatsira kuve nechokwadi chekuchinja kwemidziyo yakachengeteka.
4. Kugamuchira Yambiro Yezvakatipoteredza:Vatariri venzvimbo yedata vanogona kuseta zvikumbaridzo uye chenjedzo kuti vatarise pa-saiti, kure, kana zvivakwa zvisina kurongwa kuona kuti michina inoshanda pasi pemamiriro akachengeteka. Masensa ezvakatipoteredza senge humidity uye ma detectors emvura anobatsira kuchengetedza midziyo yakakosha uye kubvisa inodhura nguva yekudzikira kunokonzerwa nekutadza kwemidziyo yeIT. Humidity sensors inobatsira kuchengetedza humidity yakakodzera mazinga, kudzivirira nyaya dze electrostatic discharge (ESD) pane yakaderera humidity uye condensation nyaya pane yakakwira humidity. Madhinari emvura anoona kuti mvura inobva kunze here kana kuti inobuda pamapombi mukati memvura yakatonhodzwa racks.
5. Kugadzira uye Kugadzirisa Data Center Infrastructure:Masensa ezvakatipoteredza anokuita kuti uwane mafambiro, gamuchira chenjedzo, kusimudzira kuwanikwa kwenzvimbo yedata, uye chengetedza simba. Ivo vanobatsira kuona uye kudzoreredza isinga shandiswe data centre huwandu, kunonoka kudyara mari mumidziyo nezvivakwa. Nekubatanidza masensa ezvakatipoteredza neData Center Infrastructure Management (DCIM) mhinduro, maneja enzvimbo yedata anogona kutarisa tembiricha munguva chaiyo uye kuverenga inogona kuchengetedza. Kugadzirisa iyo data centre ecosystem inobatsira mukudzikisa mitengo yekushandisa uye kugadzirisa Simba Rekushandisa Kubudirira (PUE).
Nguva yekutumira: Aug-05-2023